RecallDepth

SUN DASH RADIUS 252 PN 8000809705. The device is intended to be used for the tanning of human skin.

This recall has been terminated (originally issued September 12, 2014).

Company
Jk Products & Services, Inc
Recall Initiated
July 25, 2014
Posted
September 12, 2014
Terminated
January 13, 2017
Recall Number
Z-2635-2014
Quantity
1948 units
Firm Location
Jonesboro, AR
Official Source
View on FDA website ↗

Reason for Recall

The integrity of the wires inside main electrical chord become compromised from excessive flexing (during the door open/close process).

Distribution

Nationwide Distribution.

Lot / Code Info

PN 8000809705; Serial numbers 248-1298

Root Cause

Device Design

Action Taken

The owners of the affected device will be notified via certified letter. After the recalling firm confirms ownership, a technician will be dispatched to install a door clamp and door stop, and inspect the condition of the main electrical chord.

More recalls by Jk Products & Services, Inc

View all recalls by this company →