RecallDepth

Scubapro® Recalls MK 20 Scuba Regulators for Service

This recall was issued October 2, 2006.

Company
Scubapro® Usa, Of El Cajon, Calif.
Posted
October 2, 2006
Recall Number
07501
Quantity
About 48,500 units
Official Source
View on CPSC website ↗

Reason for Recall

Over-tightening of the Yoke or Din retainer during annual servicing of these regulators could result in a stress crack and failure of the regulator. If this occurs during a dive, air supply could be interrupted, posing a drowning hazard.

Action Taken

Scubapro® USA has been providing a service upgrade kit via the authorized dealer network since May 2005 which contains a Yoke or Din retainer that prohibits over-tightening during annual service. Consumers can easily identify if the service upgrade has been completed by counting the vents on the plastic saddle located on the regulator. If the service upgrade has not been completed, the consumer should bring the regulator to any authorized Scubapro® dealer to have the service upgrade completed free of charge.

Product Images

Recalled Scuba Regulators
Recalled Scuba Regulators

Incidents & Injuries

No injuries or underwater incidents have been reported. Scubapro® USA has received eight reports of units that failed after being serviced.